CDR Tickets

Issue Number 4636
Summary Error when switching between tiers
Created 2019-07-09 13:11:28
Issue Type Bug
Submitted By Osei-Poku, William (NIH/NCI) [C]
Assigned To Kline, Bob (NIH/NCI) [C]
Status Closed
Resolved 2019-07-09 20:42:25
Resolution Fixed
Path /home/bkline/backups/jira/ocecdr/issue.246568
Description

We are getting the following error message when switching from PROD to DEV, and vice versa and that prevents us from logging into DEV. However, we can log back onto PROD even though the error message displays. This problem started yesterday.

Comment entered 2019-07-09 20:42:25 by Kline, Bob (NIH/NCI) [C]

Looks like a new Cdr.mcr got installed without running RefreshManifest. Please try again.

Comment entered 2019-07-10 10:17:02 by Englisch, Volker (NIH/NCI) [C]

Oops!  I think that was me.  Sorry!!!

I had to install the macro changes after DEV was updated with the Joule changes and I'm pretty sure I forgot to run RefreshManifest.

Comment entered 2019-07-10 11:56:48 by Osei-Poku, William (NIH/NCI) [C]

Verified. Thanks!

Attachments
File Name Posted User
TierSwitchError.png 2019-07-09 13:06:30 Osei-Poku, William (NIH/NCI) [C]

Elapsed: 0:00:00.002096