Issue Number | 3630 |
---|---|
Summary | [Summaries] Patient Summary QC Reports Missing Reference Section |
Created | 2013-07-24 17:41:18 |
Issue Type | Bug |
Submitted By | Juthe, Robin (NIH/NCI) [E] |
Assigned To | Englisch, Volker (NIH/NCI) [C] |
Status | Closed |
Resolved | 2013-09-23 16:18:25 |
Resolution | Fixed |
Path | /home/bkline/backups/jira/ocecdr/issue.110891 |
The Patient B/U and RLSO QC reports are not displaying the reference section when the option is selected to display them.
The Complementary and Alternative Medicine in Cancer Treatment summary (CDR0000446574) contains references, but the QC report suppresses the display of citations.
This may be the only patient summary with references.
Did this used to work but stopped working since we moved to CBIIT or do we know if this never worked before?
From Judy:
They did show up in QC reports before Bastion. I’m just not positive they showed up the day before, since we see them so rarely. Very few patient summaries have references, so it’s rare that we even need that feature.
Given the fact that these citations did show up before I'm wondering if the problem is related to the limited length of the URI. I'll check out the summary.
This may never have worked for patient CAM summaries. It appears that
the Citation flag for the patient CAM summaries doesn't have any effect
(probably because there didn't exist any patient CAMs with citations
when the filter/report was written).
I will look at this in a little more detail tomorrow.
The software didn't allow for patient summaries to have reference
sections displayed even though - and this is a little odd - the checkbox
existed for patient summaries. I have made changes to allow patient
summaries with references to display those in reference sections.
This was a simple fix but we should run diff reports to ensure that the
fact that patient summaries now possibly contain reference sections
won't negatively impact the inclusion of other sections.
The following program has been updated:
R12037: QcReport.py
This is ready for QC on DEV.
Verified on DEV.
Verified on QA.
Verified on Prod.
Elapsed: 0:00:00.001395