CDR Tickets

Issue Number 4112
Summary Error in Summaries TOC Lists report for IACT (CAM)
Created 2016-05-25 13:04:46
Issue Type Bug
Submitted By Juthe, Robin (NIH/NCI) [E]
Assigned To Englisch, Volker (NIH/NCI) [C]
Status Closed
Resolved 2017-01-12 18:33:28
Resolution Fixed
Path /home/bkline/backups/jira/ocecdr/issue.184977
Description

The IACT option under the Spanish menu is not working on PROD.

I'm getting a python error if I try running this report for IACT Spanish summaries only.

A problem occurred in a Python script.

D:\cdr\Log\tmpjdnp5t.html contains the description of this error.

The IACT selection is ignored (and the report still runs) if other Boards are chosen along with IACT in the Spanish section of the report.

However, if you select IACT under the English report options and select the Spanish radio button, you DO get the IACT Spanish results. It probably shouldn't work that way, but it's a workaround for the meantime.

Comment entered 2016-05-25 13:06:24 by Englisch, Volker (NIH/NCI) [C]

This error is displayed when there are no records found for the specific selection.
I've updated the report on DEV so that it doesn't run into an error anymore. However, there is still a small problem: The message indicating that there doesn't exist any record for the selected options an incorrect board is displayed.
I will fix that a little later.

Comment entered 2017-01-12 18:33:09 by Englisch, Volker (NIH/NCI) [C]

I've fixed the bug preventing the Spanish IACT summaries getting picked up. This is ready on DEV:

  • R14489: SummariesTocReport.py

Comment entered 2017-01-26 13:26:50 by Juthe, Robin (NIH/NCI) [E]

Verified on DEV.

Comment entered 2017-03-02 13:24:11 by Juthe, Robin (NIH/NCI) [E]

Verified on QA.