Issue Number | 3923 |
---|---|
Summary | Patient summary RS/BU QC Reports produce errors for modules |
Created | 2015-06-09 16:45:12 |
Issue Type | Bug |
Submitted By | Osei-Poku, William (NIH/NCI) [C] |
Assigned To | Englisch, Volker (NIH/NCI) [C] |
Status | Closed |
Resolved | 2015-07-07 16:49:04 |
Resolution | Fixed |
Path | /home/bkline/backups/jira/ocecdr/issue.162942 |
When you're in a module document in the CDR that has a Patient audience and you try to run the "Redline/Strikeout" or the "Bold/Underline " reports from the toolbar icons or macros (for Patient audience), you get the following error message:
"ERROR:
Summary Patient QC Report (B/U) valid for reformatted patient summaries
only"
Meanwhile, while in the same Module (Patient version) document and you click on the HP icons (RS and BU), you're able to successfully run the report. So the Patient macros don't work and the HP macros work for both the Patient and HP versions of module documents.
The attribute ModuleOnly attribute is not carried over by the filters in the filter set Denormalization Summary Set because there didn't exist such an attribute before. I may have to modify all of the following filters in the filter set so that I can properly identify in the filter Patient Summary QC Report Filter (CDR000158) if the correct filter set has been chosen to run the QC report:
Filter: Summary Add Board Member - Spanish (682668)
Denormalization Filter: Summary (335424)
Denormalization : Citation Denormalization (331662)
Module: Multimedia Denormalization (410709)
ModuleFilter: Summary Citation Formatting (335425)
Denormalization : Citation Formatting (258630)
ModuleFilter: Summary Reference List (335428)
Denormalization Filter: Summary Reference De-Dup (335416)
Denormalization Filter: Summary Reference Numbering (335417)
Denormalization Filter: Summary InLine Numbering (335418)
Denormalization Filter: Summary Citation Wrapper Add (335437)
Denormalization Filter: Summary Citation Wrapper Sort (335438)
Denormalization Filter: Summary Count Tables and Figures (723518)
Denormalization Filter: Summary Resolve Table and Figure Number (723519)
Denormalization Filter: Secondary Links (618263)
Denormalization for Summary Report (409593) Copy XML
In the past we had to use HP QC reports for patient summaries that had not been reformatted and patient QC reports for summaries already reformatted. I understand that all summaries have now been reformatted, so I'm changing the filters to only look at the SummaryAudience value to decide which type of report to run. Previously, only patient summaries that had KeyPoints or were CAM summaries could be run with the patient version of the QC reports.
The following filters have been updated on DEV:
CDR000153: Health Professional Summary Report-Bold/Underline
CDR000079: Health Professional Summary Report
CDR000158: Patient Summary QC Report Filter
CDR441144: Patient Summary QC Report - Bold/Underline
The following filters have been updated on DEV:
R13483: CDR000153: Health Professional Summary Report-Bold/Underline
R13483: CDR000079: Health Professional Summary Report
R13483: CDR000158: Patient Summary QC Report Filter
R13483: CDR441144: Patient Summary QC Report - Bold/Underline
The filter changes are ready for testing on STAGE.
Verified on STAGE. Thanks!
The filters have been updated on PROD. Please verify and close this ticket.
Verified on PROD. Thank you!
Can we take this out of Darwin since this is already on PROD (and closed)?
Removed from Darwin
File Name | Posted | User |
---|---|---|
Patient macro error.PNG | 2015-06-09 16:45:12 | Osei-Poku, William (NIH/NCI) [C] |
Elapsed: 0:00:00.001541