CDR Tickets

Issue Number 4385
Summary [Gauss QA Testing] XMetal login window switching between old and new
Created 2018-01-16 11:26:34
Issue Type Bug
Submitted By Osei-Poku, William (NIH/NCI) [C]
Assigned To Kline, Bob (NIH/NCI) [C]
Status Closed
Resolved 2018-01-18 14:17:25
Resolution Won't Fix
Path /home/bkline/backups/jira/ocecdr/issue.219782
Description

When logging into QA, we sometimes get the new window with all the 4 CDR tiers listed and other times, we get a window with just the 3 tiers listed. It appears the loader is switching between the old and the new windows but with no apparent pattern. This has happened to about 3 of us. I just experienced this at about 11:00 am today even though the window changed the first first time I logged (several days ago) and I have seen the new window before. The loader appears to have switched me back to the old window. I have attached screenshots of both windows.

Comment entered 2018-01-17 16:21:14 by Juthe, Robin (NIH/NCI) [E]

Hi , I think it is dependent on which tier you last logged into. If you last logged into QA, then you will receive the new, 4-tier login screen. If you last logged into PROD, you will receive the current 3-tier login screen.

Comment entered 2018-01-17 16:25:10 by Kline, Bob (NIH/NCI) [C]

Right. That toggling back and forth will no longer happen once Gauss has been deployed to all the tiers.

Comment entered 2018-01-17 21:12:42 by Osei-Poku, William (NIH/NCI) [C]

Thanks! I was able to confirm this.

Attachments
File Name Posted User
3 tier window.JPG 2018-01-16 11:18:19 Osei-Poku, William (NIH/NCI) [C]
4tierwindow.png 2018-01-16 11:18:26 Osei-Poku, William (NIH/NCI) [C]

Elapsed: 0:00:00.001453